发布时间: 2023-08-01 16:05
向着尖端电子进发,
永远立于不败之地!
今举个实际应用案例来供各位参考一下,或许由此会引起您对当今的电子行业现状产生一系列的联想,甚至会引发您对未来的科技发展动态作出深层次的思考。
今年4月份本公司为某军工单位设计定制了一款与连续脉冲高压电源相配套的干式脉冲变压器:
重复频率F=100Hz 脉冲持续时间td=0.5μS 6KVx500A/300KVx10A=3MW
紧凑型干式构造中频超高压窄脉冲变压器 接阻容兼性负载 处于无歇/连续/长期工作状态 带风扇作强迫风冷
本公司按照客户所提供的技术要求进行设计并定制出了这款变压器。变压器装机试用后发现在满载状态下次级输出电压的降幅偏大了不少。在得知了试用效果方面的信息以后,本公司立即作出了回应:“请将你们对脉冲上升时间tr、脉冲持续时间td、脉冲下降时间tf、脉冲恢复时间tb以及重复频率F这五个时间概念所给出的定值依据详细告诉我们,以便于我们帮助你们从中切实排查出出现这种问题的根源所在。”在收到邮件以后我们随即逐条进行推算最终发现了他们原定的脉冲持续时间td=0.5μS实在偏小了不少,于是我们直接告知他们将此值由td=0.5μS提升到0.71μS时才可以算得上是比较恰当。随后我们跟踪设计并重新定制出了该款的修正版变压器供他们继续做试验。不久我们就收到了他们的正式回应:“问题已被彻底解决,试验效果非常理想。”
现将两次设计定制的变压器基本信息列表作出如下说明:
初次级电压和电流 | 6KVx500A/300KVx10A | 6KVx500A/300KVx10A |
脉冲持续时间 | (原定值)0.5μS | (修正值)0.71μS |
重复频率 | 100Hz | 100Hz |
配套铁芯型号 | CD40x80x150(232) | CD40x80x160(234) |
配套铁芯重量 | 18.69Kg | 19.17Kg |
初次级绕组匝数 | 6T/300T | 8T/400T |
变压器外形尺寸 | 长53cmx宽37cmx高27.5cm | 长53cmx宽37cmx高28.5cm |
变压器重量 | 69Kg | 71Kg |
其实,本公司对客户所提出的最关键的技术参数惯来都会主动给出修正意见从而得到最佳参数定值、最终形成最佳设计方案。不过,对于军工单位的设计定制,由于信息保密,我们自然不便于追问得过早、追问得过细。顺此说明。
另外,本公司在发货的同时历来都会主动向客户提交变压器的绕制数据以及变压器出厂前所做的测试结果等原始依据供参照和存档。
特种干变绝对能够算得上是特种电源装置里面的最核心最关键最致命的部件了,尤其是为那些被预埋在深山中和海岛中的超大型数字化带遥控的电子对抗设备相配置的尖端特种电源所配套的特种干变方面的专业技术那就显得更加弥足珍贵啰!
向着尖端电子进发,永远立于不败之地!
手机:18900869046 佛山鼎秀特种变压器有限公司
18924129865 总经理:翟崖松 撰稿
邮箱:yxbyq2009@163.com 2023年08月01日
Move towards cutting-edge electronics, Always invincible!
Let me cite a practical application for your reference, may be able to cause a series of associations of the current situation of the electronics industry, and even cause the future development of science and technology in-depth thinking.
In April this year, Foshan Dingxiu transformers Co. (Dingxiu Transformer) design customized with continuous pulse high-voltage power supply supporting dry-type pulse transformer (the main technical indicators are as follows) for a military enterprise)
o Repetition frequency F=100Hz
o Pulse duration td=0.5μS
o Pulse power 6KVx500A/300KVx10A=3MW
o Compact dry type IF UHV narrow pulse transformer
o Resistor compatible load
o Unpowered/continuous/long-term operation
o Forced air cooling with fan
We designed and customized this transformer according to the technical requirements provided by the customer. After the transformer was installed and tested, it was found that the secondary output voltage dropped considerably under full load. After learning the test results, our company immediately responded: "Please write down the five time points of pulse rise time tr, pulse duration td, pulse fall time tf, pulse recovery time tb and repetition frequency F. The valuation basis given by the concept will be told to us in detail, so that we can help you to find out the root cause of this problem." After receiving the email, we calculated them one by one and finally realized that their original pulse duration td=0.5μS was indeed too small, so we directly told them that it would be more appropriate to increase this value from td=0.5μS to 0.71μS. Then, we followed up the design and re-customized the modified version of the transformer for them to continue their experiments. Soon, we received an official reply from them: "The problem has been completely solved and the experimental results are very satisfactory".
The list of basic information of the two transformers designed and customized is explained below:
Primary/ secondary voltage and current | 6KVx500A/300KVx10A | 6KVx500A/300KVx10A |
Pulse duration | 0.5μS(original value) | 0.71μS(modified value) |
Repetition frequency | 100Hz | 100Hz |
Supported core model | CD40x80x150 (232) | CD40x80x160 (234) |
Supported Core Weight | 18.69kg | 19.17kg |
Primary/Secondary Winding Turns | 6T/300T | 8T/400T |
Dimensions | L53cmxW37cmxH27.5 cm | L53cmxW37cmxH28.5cm |
Transformer weight | 69 kg | 71 kg |
In the actual operation process, our company will actively propose amendments to the most critical technical parameters proposed by the customer, so as to obtain the best parameter values, and ultimately form the best design program. However, for the design customization of the military industrial enterprises, due to the confidentiality of the information, we are naturally inconvenient to ask too early and too detailed. According to this description.
In addition, our company has always taken the initiative to submit the original vouchers such as winding data and test results before the transformer leaves the factory to the customer for reference and archiving.
Special dry-type transformer in the special power supply equipment, especially for those pre-buried in the deep mountains and islands of the ultra-large remote control digital electronic countermeasures equipment, can definitely be called the core, critical and deadly components. And support cutting-edge special power supply special dry-type transformer expertise is invaluable!
Move towards cutting-edge electronics, Always invincible!
Cell phone:18900869046 Foshan Dingxiu Special Transformer Co.
18924129865 General Manager: Mr. Zhai Yasong
E-mail: yxbyq2009@163.com August 1, 2023